对于小(≤4cm)肾实体肿块的透明细胞肾细胞癌(RCC), 5层CT评分算法可能是一种临床有用的诊断工具。

72-year-old man with right interpolar 3.2-cm renal mass. Axial CT images in the (A) unenhanced, (B) corticomedullary, and (C) nephrographic phases at the same level depict the mass (arrow, A and C), which shows avid heterogeneous enhancement. Circular ROIs were placed in the most enhancing component of the mass and in ipsilateral renal cortex (circles, B), to determine the mass-to-cortex corticomedullary attenuation ratio. Heterogeneity scores were assigned subjectively using a 5-point Likert type-scale. These two features were used to inform development of the CT score. In this patient, the mass showed avid enhancement (mass-to-cortex corticomedullary enhancement ratio >0.75) and was considered completely heterogeneous (heterogeneous score, 5) by both radiologists, resulting in CT score 5. Nephrectomy revealed clear-cell renal cell carcinoma.


June 30, 2022 —According to ARRS’ American Journal of Roentgenology (AJR), a 5-tieredCTscoring algorithm may represent a clinically useful tool for diagnosis ofclear-cell renal cell carcinoma(RCC) in small (≤4 cm) solidrenal masses.

“A 5-tiered renal CT algorithm, including mass-to-cortex corticomedullary attenuation ratio and heterogeneity score, had substantial inter-observer agreement, moderate AUC and PPV, and high NPV for diagnosing clear-cell RCC,” concludedNicola Schiedafrom the department of medical imaging at Canada’s Ottawa Hospital.

Schieda and colleagues’ study included 148 patients (mean age, 58 years; 73 men, 75 women) with 148 small (≤4 cm) solid (>25% enhancing tissue) renal masses that underwent renal-mass CT (unenhanced, corticomedullary, and nephrographic phases) before resection between January 2016 and December 2019. Two radiologists independently evaluated CT examinations and recorded calcification, mass attenuation in all phases, mass-to-cortex corticomedullary attenuation ratio, and heterogeneity score (5-point Likert scale, assessed in corticomedullary phase).

Ultimately, Schieda et al’s 5-tiered CT scoring algorithm—including mass-to-cortex corticomedullary attenuation ratio and heterogeneity score—had substantial interobserver agreement (weighted kappa=0.71) and achieved AUC for diagnosing clear-cell RCC of 0.75 (95% CI, 0.68-0.82) for reader 1 and 0.72 (95% CI, 0.66-0.82) for reader 2.

“If validated,”the authors of this AJR article acknowledgedCT算法可能是诊断透明细胞肾细胞癌的一种有用的临床工具。

For more information:www.arrs.org

Related Content

Dr. Milena Cavic, Institute for Oncology and Radiology of Serbia
News|Lung Imaging

August 8, 2022 — Representatives from the Diagnostics Working Group of the IASLC Early Detection and Screening Committee ...

TimeAugust 08, 2022
arrow
Xoran Technologies announces that last month it received FDA 510(k) clearance for TRON — a truly mobile, full-body fluoroscopy, computed tomography (CT) X-ray system.
News|Computed Tomography (CT)

August 4, 2022 — Xoran Technologies announces that last month it received FDA 510(k) clearance for TRON — a truly mobile ...

TimeAugust 04, 2022
arrow
EHR screenshot showing sidebar text displayed to referring clinicians after placing orders for body CT (neck, chest, or abdomen and pelvis), describing iohexol shortage and providing appropriate strategies for iodinated contrast media conservation.
News|Contrast Media

August 3, 2022 — According to an open-access article in ARRS’ American Journal of Roentgenology (AJR), electronic health ...

TimeAugust 03, 2022
arrow
Bracco诊断公司宣布,美国食品和药物管理局(FDA)授予Iomeron®(iomeprol注射液)进口自由裁量权,以解决目前碘化造影剂短缺的问题。
News|Contrast Media

2022年8月2日-随着放射界继续解决供应中断的问题,一项新的更新已宣布……

TimeAugust 02, 2022
arrow
Dunlee unveiled its new oncology bundles for the first time this year, launched at the 2022 European Congress of Radiology
News|ECR

July 25, 2022 — Dunlee unveiled its new oncology bundles for the first time this year, launched at the 2022 European ...

TimeJuly 25, 2022
arrow
According to ARRS’ American Journal of Roentgenology (AJR), an AI tool for detection of incidental pulmonary embolus (iPE) on conventional contrast-enhanced chest CT examinations had high NPV and moderate PPV, even finding some iPEs missed by radiologists
News|Computed Tomography (CT)

July 21, 2022 — According to ARRS’ American Journal of Roentgenology (AJR), an AI tool for detection of incidental ...

TimeJuly 22, 2022
arrow
the findings could be used to inform the committee on BI-RADS regarding the possible incorporation of the MBI lexicon into the BI-RADS Atlas
News|2022世界杯篮球预选赛赛程

2022年7月21日—根据ARRS的《美国x线学杂志》(AJR),了解恶性肿瘤的可能性……

TimeJuly 22, 2022
arrow
3DR Labs, an Accumen company, today announced the launch of its Cardiac Center of Excellence and Imaging Excellence Advisory Services to support radiology departments in hospital and outpatient settings nationwide
News|AHRA

July 18, 2022 — 3DR Labs, an Accumen company, today announced the launch of its Cardiac Center of Excellence and Imaging ...

TimeJuly 19, 2022
arrow
Iodixanol Injection, USP is the first U.S. FDA-approved generic iso-osmolar, dimeric iodinated contrast media agent, which is used during diagnostic x-ray-based imaging such as computed tomography (CT) scans
News|Contrast Media

July 18, 2022 — Fresenius Kabi announced today it will introduce a portfolio of generic contrast media agents in the ...

TimeJuly 18, 2022
arrow
KA Imaging, a company that develops innovative X-ray imaging solutions, announced the initial results from a study examining the diagnostic value of single-exposure dual-energy subtraction radiography in lung lesion detection
News|Lung Imaging

July 13, 2022 — KA Imaging, a company that develops innovative X-ray imaging solutions, announced the initial results ...

TimeJuly 13, 2022
arrow
Subscribe Now