System geometry, imaging mechanism, and performance evaluation of a self-collimating SPECT for fast dynamic cardiac imaging

System geometry, imaging mechanism, and performance evaluation of a self-collimating SPECT for fast dynamic cardiac imaging. Image courtesy of Debin Zhang, Xingchun Zheng, Yifan Hu, Zhenlei Lyu, Yaqiang Liu, and Tianyu Ma, Tsinghua University, Beijing, Beijing, China; Zuo-Xiang He, Beijing Tsinghua Changgung Hospital, Tsinghua University, Beijing, Beijing, China; and Rutao Yao, University of Buffalo, State of New York, East Amherst, New York.


June 15, 2022 — Acardiac SPECTimaging system performs scans 10 to 100 times faster than current SPECT systems, according to newresearch presentedat theSociety of Nuclear Medicine and Molecular Imaging2022 Annual Meeting. The advantages of self-collimation SPECT include dramatically shortened scan time, better image quality, increased patient throughput, and reducedradiation exposureto patients.

Heart disease—which includes heart attack,heart failureand arrhythmias—is the leading cause of death among adults in the United States. TheCenters for Disease Control and Preventionreports that nearly 660,000 Americans die from heart disease each year, accounting for one out of every four deaths.

The new system is constructed with the concept of self-collimation; active detectors in a multi-layer architecture carry out the dual functionality of detection and collimation. This concept improves the conventional SPECT paradigm, in which a mechanical collimator is the backbone but also the bottleneck of imaging performance.

“SPECT is an important noninvasive imaging tool for the diagnosis and risk stratification of patients with coronary heart disease,” said Debin Zhang, a doctoral student in the Department of Engineering Physics at Tsinghua University in Beijing, China. “However, conventional SPECT suffers from long scan time and poor image quality as a result of relying on a mechanical collimator. The new SPECT system is capable of performing fast-framed dynamic scans with high quality.”

To break away from the constraints of mechanical collimator, the research team designed a self-collimatingcardiac SPECTsystem. They used a multilayer, interspaced mosaic-patterned detector that carries out a dual function of photon detection and collimation. The signal-to-noise ratio of the system is further improved with a random pattern of apertures on the metal plate, which also functions as part of the collimation. The system had an average sensitivity of 0.68 percent in the field of view and was able to identify the defect in a cardiac phantom in as little as 2 seconds.

“The technology proposed in this work may drive a paradigm shift in all single-photon-emission-based molecular imaging and nuclear medicine technologies,” remarked Tianyu Ma, PhD, associate professor of Engineering Physics at Tsinghua University. “The new detector design opens up a broad range of possibilities for development of new imaging systems with better image quality, higher speed, and better diagnostic accuracy in molecular imaging.”

Abstract 250. “Feasibility study of a self-collimating SPECT for fast dynamic cardiac imaging,”Debin Zhang, Xingchun Zheng, Yifan Hu, Zhenlei Lyu, Yaqiang Liu, and Tianyu Ma, Tsinghua University, Beijing, Beijing, China; Zuo-Xiang He, Beijing Tsinghua Changgung Hospital, Tsinghua University, Beijing, Beijing, China; and Rutao Yao, University of Buffalo, State of New York, East Amherst, New York.

For more information:www.snmmi.org

Find more SNMMI22 coverage here

Related Content

The SpeedBird and Concorde device platforms are based on TransMed7’s patented Zero5 work element composed of a fused, single element constructed from 3 hypotubes, laser cut and welded to form articulable twin cutter blades at the end of a rotating open tube
News|Ultrasound Imaging

August 10, 2022 — Butterfly Network, Inc., a digital health company transforming care with handheld, whole-body ...

TimeAugust 10, 2022
arrow
Feature|Magnetic Resonance Imaging (MRI)| Christine Book

August 10, 2022 — The imaging community has lost a legend, recognized for having revolutionized the field of diagnostic ...

TimeAugust 10, 2022
arrow
Siemens Healthineers has announced the Food and Drug Administration (FDA) clearance of the ARTIS icono ceiling, a ceiling-mounted angiography system designed for a wide range of routine and advanced procedures in interventional radiology (IR) and cardiology
News|Mobile C-Arms

July 29, 2022 — Siemens Healthineers has announced the Food and Drug Administration (FDA) clearance of the ARTIS icono ...

TimeJuly 29, 2022
arrow
House-passed Appropriations Bills Include Key Measures to Improve Nuclear Medicine Patient Safety
News|Nuclear Imaging

July 27, 2022 — Patients for Safer Nuclear Medicine, a coalition of 29 patient advocacy organizations representing ...

TimeJuly 27, 2022
arrow
Aidoc artificial intelligence
News|Artificial Intelligence

July 26, 2022 — Aidoc, a leading provider of AI healthcare solutions, today announced a partnership with UofL Health, a ...

TimeJuly 26, 2022
arrow
According to ARRS’ American Journal of Roentgenology (AJR), an AI tool for detection of incidental pulmonary embolus (iPE) on conventional contrast-enhanced chest CT examinations had high NPV and moderate PPV, even finding some iPEs missed by radiologists
News|Computed Tomography (CT)

July 21, 2022 — According to ARRS’ American Journal of Roentgenology (AJR), an AI tool for detection of incidental ...

TimeJuly 22, 2022
arrow
the findings could be used to inform the committee on BI-RADS regarding the possible incorporation of the MBI lexicon into the BI-RADS Atlas
News|2022世界杯篮球预选赛赛程

July 21, 2022 — According to ARRS’ American Journal of Roentgenology (AJR), understanding the likelihood of malignancy ...

TimeJuly 22, 2022
arrow
NorthStar will provide Clovis with its environmentally preferred, high purity non-carrier-added (n.c.a.) Ac-225
News|Radiopharmaceuticals and Tracers

July 20, 2022 — -NorthStar Medical Radioisotopes, LLC, a global innovator in the development, production and ...

TimeJuly 20, 2022
arrow
Radialis Inc. today announced that it has received clearance to market the Radialis PET Imager, an organ-targeted positron emission tomography (PET) system, in the United States
News|PET Imaging

July 19, 2022 — Radialis Inc. today announced that it has received clearance to market the Radialis PET Imager, an organ ...

TimeJuly 19, 2022
arrow
3DR Labs, an Accumen company, today announced the launch of its Cardiac Center of Excellence and Imaging Excellence Advisory Services to support radiology departments in hospital and outpatient settings nationwide
News|AHRA

2022年7月18日—伏隔核公司3DR Labs今天宣布成立心脏卓越和成像中心……

TimeJuly 19, 2022
arrow
Subscribe Now